Beambrace / Frame systems

Concrete frame systems, compared

Six ways to build a reinforced-concrete frame. Pick one to see its elevation and plan, typical spans and slab depths, the formwork it needs and how it resists earthquakes.

3.0 m 6.0 m next slab, ready to pourABCD
ElevationBeam and slab frame
ABCD123Beams on every gridline
Plan, one floorTypical bay 6.0 m

Beam and slab frame

The classic frame: columns carry beams, beams carry the slab. It copes well with irregular layouts and openings, but every beam is extra formwork and the ceilings have downstands.

  • Works with irregular column grids
  • Easy to frame openings and stairs
  • Beams add lateral stiffness
  • Most formwork labor per m²
  • Downstand beams cut clear height and complicate pipe and duct routes
Typical span
4–8 m
Depth
Slab 120–180 mm; beams about 1/12 of the span
Formwork
Deck plus beam sides and soffits; the most labor per m²
Build speed
Slower cycle
Earthquakes
Beams and columns form a moment frame; joints need careful seismic detailing
Best for
Irregular grids, heavy loads, buildings where downstand beams are acceptable

Typical ranges for early planning. Your structural design sets the final spans, depths and reinforcement.

Which systems suit your column spacing?

Drag to your typical distance between columns. Systems whose usual span range covers it turn dark.

7.0 m

Usually suits: Beam and slab frame, Flat plate, Flat slab with drop panels, One-way ribbed slab, Wall-frame (dual) system.

Beam and slab frame
Flat plate
Flat slab with drop panels
Waffle slab
One-way ribbed slab
Wall-frame (dual) system
3 m6 m9 m12 m15 m

All six side by side

The same comparison as a table, for your design meetings.

SystemTypical spanDepthFormworkBuild speedBest for
Beam and slab frame4–8 mSlab 120–180 mm; beams about 1/12 of the spanDeck plus beam sides and soffits; the most labor per m²Slower cycleIrregular grids, heavy loads, buildings where downstand beams are acceptable
Flat plate5–7.5 m200–250 mm, roughly span ÷ 30Flat deck only; the quickest to set and stripFastest cycleApartments and hotels on regular grids
Flat slab with drop panels7–10 mSlab 200–275 mm plus drops under the columnsFlat deck plus a drop-panel box at each columnFastCar parks, retail and heavier floor loads
Waffle slab9–14 m300–500 mm overallFlat deck with reusable domes; solid heads at the columnsMediumOffices, halls and long-span commercial floors
One-way ribbed slab6–10 m250–400 mm overallPans or fillers between ribs; beams on the gridlinesMediumRectangular grids with one long span direction
Wall-frame (dual) system4–9 mAny slab type; walls 200–300 mm thickWall panels for cores and walls, plus the slab systemSet by the slab; walls lead each floorMid- and high-rise buildings in seismic regions such as Armenia

Not sure which system fits your building? Send the drawings and we'll tell you.